SymptomCause and fix
502 Bad Gateway when creating a dataset or testing a database on TrinoTrino answered HTTP 406. Egret sends X-Forwarded-Proto; set http-server.process-forwarded=true on Trino.
429 Too Many Requests at sign-inThe local sign-in limit is 5 attempts per 5 minutes per address and email; rejected attempts keep the window open. Wait, or restart the server (the limiter is in memory) in a throwaway instance.
A workflow execution stays in RunningThe workflow worker is off by default. Set EGRET_WORKFLOW__WORKER_ENABLED=true (and EGRET_WORKFLOW__SCHEDULER_ENABLED=true for triggers).
kubernetes unavailable; engine provisioning disabled in the logThere is no Kubernetes cluster. Register external engine still works; Add engine does not.
Registering a database with a secret fails[secrets] master_key is not set.
/control-plane/config renders a blank pageKnown issue; the page is not linked from the UI.